Rollershield Flashing Tape is a lightweight roll flashing material with superior strength and the ability to bridge most gaps or voids common in construction.

Embedded into wet Rollershield, it is used at flashing transitions with Master Wall® Rollershield air & water barrier applications. The tape easily embeds into wet Rollershield and dries to a highly reinforced yet flexible flashing.

  • Lightweight
  • Embeds easily
  • Thin, won’t build up wall surface

Stocking Locations: 30058 • 77474• 84651

Tape Size
Rollershield Flashing Tape is available in the following size rolls:

4″x180′ (10.2cm x 54.9m)
6″x180′ (15.2cm x 54.9m)
9″x180′ (22.9cm x 54.9m)

Packaging
4″: 18 rolls per case.
6″ & 9″: 12 rolls per case.

Coverage Estimate (4×8 sheets)

Square Footage x 0.37 = linear feet of tape Add linear footage around windows, doors and other openings. (coverage is not guaranteed)

Application Procedure

General—The substrate must be clean, dry, structurally sound and free of efflorescence, oil, grease, form release agents and curing compounds. Test painted surfaces to verify bond.

Job Conditions – Air and substrate temperature for application of Rollershield Flashing Tape must be 40°F (5°C) or higher. Follow Rollershield temperatures and condition requirements.

Temporary Protection – Protect from weather until the Rollershield products have set up.

Surface Preparation – Surface temperature must be above 40°F (5°C). Surface must be cured, clean, dry, structurally sound and free of efflorescence, oil, grease, form release agents, and curing compounds.

Installation
General – Rollershield Flashing Tape is embedded into wet Rollershield at flashing transitions (sheathing to framing, flashing, penetrations, etc.) and at sheathing board joints. Apply a generous layer of either product using a trowel, brush or roller and immediately embed the Rollershield Flashing Tape into the product and draw it tight and smooth working from the center to the edges.

Windows – The unique properties of the Rollershield air/water barrier system allows window flashing prior to the Rollershield wall application. Apply Rollershield at least 2″ (51 mm) either side of the window opening. Use a “butterfly” at corners to complete the application making sure it covers all corner joints. For best results make sure the Rollershield covers the entire head, jamb and sill areas. The use of sill wedges or water stops is encouraged.

Sheathing Applications — Apply Rollershield at least 2″ (51 mm) either side of the sheathing board joint. Immediately embed the Rollershield Flashing Tape into the wet Rollershield and smooth with a trowel, centering it over the joint. Lap Rollershield Mesh Tape 2″ (51 mm) minimum

Rollershield field application can begin as soon as the Rollershield is dry to the touch.

Information contained in this product data sheet conforms to the standard detail recommendations and specifications for the installation of Master Wall® Inc. products and is presented in good faith. Master Wall® Inc. assumes no liability, expressed or implied as to the architecture, engineering, or workmanship of any project. This information may be concurrent with, or superseded by other applicable documents, such as specifications and details. Contact Master Wall® Inc. for the most current product information.