Technical Bulletins and tips on installation of our systems. Some are large files and take some time to download. Our Full Technical Bulletin Binder is continually updated to insure you have the latest information.
MW#104 AFM Perform Guard Termite Resistant Insulation Board
MW#107 AIA-CES Architectural Training
MW#112 Cleaning and Maintenance
MW#114 Dryflekt Molded Flashings
MW#118 Product and System Comparison Chart
MW#125 Field Observation Forms
MW#128 Remedial Repairs At Grade
MW#129 Repairing Master Wall® Systems
MW#131-190501 Sealant Use With Master Wall Systems
MW#133 Universal Drainage Tracks
MW#136-100101 Acrylic Polymers
MW#137 EIFS Inspection Guidelines
MW#138-120101 R-Values of Common Building Materials
MW#140-020102 Floor Line Expansion Joints
MW#141-030102 Prefabricated Architectural Shapes
MW#142-080102 Water Barrier Installation
MW#143-010103 Minimum Design Weights of Materials
MW#145-080103 Finish Drying and Color Variations
MW#146-100103 Curing & Drying of Master Wall & Other Products
MW#147-120103 New Pressure Treated Wood
MW#148-010104 Thermal Movement in Building Components
MW#149-020104 Sealant Joint Design
MW#151-040104 Insulation Thickness
MW#152-090115 Plastic Components Ultra Lath
MW#153-070104 Substrate Changes
MW#154-080104 Decorative Options
MW#155-090104 Graffiti Protection
MW#156-010105 Pre/Post Application Checklist
MW#158-100105 Drainage Options
MW#159-010106 Texture/Color Effects
MW#160-040106 Light Reflectance Values
MW#161-050106 Brick Stencil Patterns
MW#162-060106 Fade Resistance of Finishes
MW#163-080106 Vintique Techniques
MW#164-090106 Versatex 0.5 Texturing Techniques
MW#165-120107 Stucco Finishing
MW#166-010108 EIFS or Not EIFS?
MW#167-201201 Metal Building Strategies
MW#168-100119 ASTM E119 Fire Rated Wall Assemblies
MW#169-070111 Master Wall Foam Shapes
MW#170-080111 Efflorescence Considerations
MW#171-080111 Dark Color Strategies
MW#172-090111 Cold Weather Application Strategies
MW#173-050115 Painted Surfaces Recommendations
MW#174-110111 Specifying Fluid Applied Air and Water Barriers
MW#175-120111 Wind-Rated Assemblies
MW#176-020112 Window Head Flashing
MW#177-040114 Continuous Insulation (ASHRAE 90.1, 2012 IECC)
MW#178-070114 Cemplaster Stucco Control Joint Option
MW#180-170301 Tight House Syndrome
MW#181-190101 Metallic Finishes Tips and Tricks
MW#183-190401 DuroTone Pigments
Discontinued Bulletins (for reference only)
MW#102-120497 Drainage Systems, MW#105-100109 Applicator Training & Applicator Certificates, MW#106-050109 Warranties, MW#108-061598 Acrylic Finishes Over Stucco, MW#110-081598 Testing, MW#111-101598 BOCA, MW#116-050199 BOCA Research Report 98-35, MW#117-070199 ICBO ER-5517/SBCCI #9631A, MW#119-010100 ICBO ER-5362, MW#120-020100 Building Codes, MW#126-011700 Enka Rain Screens – replaced with Data Sheet, MW#139-010102 Texas Department of Insurance, MW144-020103 Interior Applications – replaced with new system, MW#135-090901 Fastening Systems – Replaced with Data Sheet
Supplemental Specifications
Sealant Specification (Word)
Roofing Specification
Sheet Metal Specification
Interior Sealant Specification
Window/Door Specification
AIA-CES Discovery
Architects, contact your Regional Manager for a Lunch and Learn with Master Wall Inc®.
Take the course here: Stucco Cladding Options
Courses Offered
Course Title: Stucco Cladding Options
Description: Description: Stucco and stucco-look claddings such as Exterior Insulation and Finish Systems (EIFS) are popular options in today’s building vernacular. This program explores how these claddings are used with the new building code requirements for energy efficiency define din ASHRAE 90.1 (2010) and the 2012 IECC. The program explores air barrier options as well as the new requirements for insulation and drainage options.
Course Information Link here.
Learning Units: 1
Credit Designations: LU
Course Format: Instructor-led face-to-face
Learning Objective 1: Outline and recognize the many positive attributes of locating rigid insulation to the exterior of traditional wall assemblies such as enhanced R-value, dew point management and improved energy efficiency.
Learning Objective 2: Define and fully understand how stucco, stucco claddings and Exterior Insulation and Finish Systems (EIFS) can integrate the new code requirements into their assemblies.
Learning Objective 3: Examine how stucco claddings and Exterior Insulation and Finish Systems (EIFS) fit into today’s sustainable design practices and contribute to attaining of Leadership in Energy and Environmental Design (LEED) credits.
Learning Objective 4: Explore how the energy efficient package can be designed for a variety of appearances.
Activation Date: 03/20/2014
Expiration Date: 03/19/2017
Course Approval Status: Approved
Basic Training Series
Learn the basic detail techniques for Master Wall Inc.® Aggre-flex and Rollershield Drainage Exterior Insulation and Finish Systems (EIFS). Basic product application and business information is also included.
Product Videos
Our videos of product application
Links
Additional Information
Contact Technical Services
800-755-0825
p 706-569-0092
f 706-569-6704