Rollershield-RS is a high quality 100% acrylic flexible air and water barrier.    Rollershield-RS is intended for roller or spray application but also can be troweled or brushed into place.  Rollershield-RS forms a continuous air and water barrier that protects approved substrates from incidental water damage.

Features & Benefits

Rollershield Hotel

Rollershield Hotel

  • 100% Coverage
  • Doesn’t rattle in the wind
  • Vapor permeable with low air infiltration rate
  • Used as water barrier and flashing

LEED Information

VOC: <1% by Weight
VOC: 10 g/l
Manufacture Locations:

30058 • 77474• 84651


Systems

  • Rollershield Drainage EIFS
  • Rollershield LAB
  • Cemplaster Fiberstucco
  • Common Cladding Systems

Packaging: 5 gallon (19L) pail

Pail Weight: 60 lbs (27 kg)

Shelf Life: 2 years

Coverage (estimated per pail)
Roller: 450-500 sf (42-46 sm)
Spray: 300-350 sf (28-32.5 sm)
Trowel: 200-250 sf (18-23 sm)

Drying & Recoat

Dry to Touch: 1 hour @ room temperature, Recoat Time: 2 hours @ room temperature,

Drying Time: 12 hours @ room temperature at room temperature, working and drying time will vary with temperature and humidity

Application Range: 40-110F (5-43C)

Exposure: 30 days maximum for EIFS*, 6 months maximum for other claddings.
*surface must be clean and dry prior to application of EIFS


Approved Substrates

Exterior gypsum sheathing
(ASTM C1396)
Dens Glass Gold®
GlasRoc®
FiberBond®
Gold Bond e2xp®
Durock®
PermaBase®
ProTEC ®
Util-A-Crete®
Concrete
Brick
Masonry
Exterior Plywood
Oriented Strand Board
Others approved in writing


Application Procedure

Job Conditions – Air and substrate temperature for application of Rollershield-RS must be 40°F (5°C) or higher and must remain 40°F (5°C) or higher for a minimum of 24 hours. Provide temporary protection to protect the wall system from damage until permanent flashings, caps and sealants are installed. Store materials within prescribed temperature limits and out of direct sunlight. Working and drying times are based upon normal room temperature conditions and will vary with temperature and humidity.

Preparation – The substrate must be approved by Master Wall Inc., clean, dry, structurally sound and free of efflorescence, oil, grease, form release agents and curing compounds or anything that would affect bond. Painted surfaces are not acceptable and must be removed. Substrates must be flat and free of fins or planar irregularities greater than 1/4” in 10’-0” (6.35 mm in 3.05m).

Concrete – Must have cured a minimum of 28 days prior to the application of Rollershield-RS. If form release agents or curing compounds exist on the surface, they must be removed with a solution of muriatic acid or similar product (with appropriate precautions). Remove any residual acid by flushing with water.

Brick/Masonry – If joints are not struck flush, multiple coats may be required. Contact Master Wall for more information.

Sheathing Applications – Sheathing gaps must be less than 1/4” (6.4 mm). For gaps larger than 1/4” (6.4 mm) WeatherStop Tape or Rollershield Flashing Tape may be used. Gap wood-based sheathing per manufacturers recommendations, typically 1/8” (3.2 mm) minimum.

Mixing – Thoroughly stir Rollershield-RS into a homogenous consist
ency. Do not add water, over mix, or add accelerators or retarders to Rollershield-RS.

Application – Rollershield-RS is applied by first treating the joints and
fastener locations where sheathing is used, then coating the entire surface using brush, roller, trowel or airless spray equipment techniques. When using a foam roller, a maximum ¾” (19 mm) nap is recommended. Apply Rollershield-RS in an even, continuous coat, maintaining a wet edge of approximately 15 mils thickness. Oriented Strand Board and other porous substrates require two (2) coats of Rollershield-RS. For moisture protection, Rollershield-RS must be applied as a continuous barrier of 10 mils dry thickness with no breaks or skips, although some areas will appear lighter than others due to the application process. The Rollershield-RS application need not look like a painted surface.

Joint Treatment—Apply a thin layer of Rollershield-RS to the joints and embed Rollershield Flashing Tape into the wet mixture and trowel smooth. Alternatively place and center Rollershield Mesh over all joints, corners and gaps in the substrate. Immediately embed Rollershield-RS into the reinforcing mesh and spot fasteners using a paint brush or trowel and allow to dry.

Rollershield-RS may be flashed into window, door and other openings using the same techniques for sheathing applications. Any remaining gaps should be filled with Master Wall Rollershield-TG (Trowel Grade) or SuperiorFlash.

Wall Treatment—Apply Rollershield-RS to the wall surface using the foam roller, trowel or by spray applying and backrolling to a uniform thickness of 15 mils wet, 10 mils dry with no pinholes or voids.

Clean Up-Tools and equipment can be cleaned with soapy water when Rollershield-RS is wet.

Limitations – Not for use as an exterior finish, note exposure limitations on top of page.

Spray Application

Rollershield is compatible with GRACO and Titan airless spray equipment with the following specifications:
• Minimum 1 gallon per minute output.
• Minimum hose width of 3/8 inch.
• Minimum tip size of 0.027–0.031.

Minimum pressure requirement to spray of 2,000 psi at the gun with an airless sprayer rated no lower than 3,300 psi. Remove all filters in sprayer and gun before application.

Hopper Gun: 3/16″-1/4″ (6-6.5 mm) orifice, 23-25 psi.

Rollershield Properties

ASTM C297 Tensile Bond
Dens Glass Gold 31.6 psi
Exterior Gypsum 28.2 psi
OSB 40.4 psi
Plywood 79.1 psi
Cement Board 70.6 psi
Copper 185.1 psi
Galvanized Steel 180.8 psi
Rigid PVC 168.2 psi
Aluminum 184.2 psi
Color Coated Aluminum 203.5 psi
Stainless Steel 183.0 psi

ASTM D1970
@ 22 mils dft Pass

ASTM D2247 Water Resistance/ICC-ES AC212
Exterior Gypsum Pass
Dens Glass Gold Pass
Cement Board Pass
Plywood Pass
OSB Pass

ASTM E-84 Combustibility
Flamespread-5
Smoke Developed-5

ASTM E96 Water Vapor Transmission
203 g/24 hr/m2
30.5 perms

ASTM E2178 Air Permeability
0.0002 cfm/ft2 at 1.57 psf

ASTM E2273 EIFS Drainage Performance ICC-ES AC212

99.2% Efficiency

ASTM E2357 Air Leakage Resistance
0.003 L/s.m2 @ 75 Pa
0.02 L/s.m2 @ 300 Pa

ICC-ES AC212 Full Scale Conditioning and Water Testing

Pass

ICC-ES AC212 Freeze Thaw
Plywood Pass
Cement Board Pass
OSB Pass
Exterior Gypsum Pass
Dens Glass Gold Pass

ICC-ES AC212 Weathering, 55 cm Head
Exterior Gypsum Pass
Dens Glass Gold Pass
Cement Board Pass
OSB Pass
Plywood Pass

NFPA 285 Multi-Story Fire Test
Pass

Information contained in this product data sheet conforms to the standard detail recommendations and specifications for the installation of Master Wall® Inc. products and is presented in good faith. Master Wall® Inc. assumes no liability, expressed or implied as to the architecture, engineering, or workmanship of any project. This information may be concurrent with, or superseded by other applicable documents, such as specifications and details. Contact Master Wall® Inc. for the most current product information.