Class-leading, durable architectural coating with hydrophobic properties formulated with acrylic polymers. Increased durability and film formation. Hydrophobic properties bead rainwater, keeping the building cleaner.


Features & Benefits

  • Hydrophobic, beads water and keeps buildings cleaner
  • Flat sheen compliments architecture
  • 100% Acrylic Polymers for durability
  • UV activated, performance improves with exposure
  • Water-based – easy clean up with water

LEED Data

VOC: <50 g/l Manufacture Locations: 30058 • 77474 • 84651 Recycled Content: 0%


Packaging/Shelf Life/Storage

Sheen: Flat

Packaging: 1 gallon (3.8L) and 5 gallon (19L) pail

Tint Bases
White Base
Deep Base
Ultra Deep Base

Pail Weight: 58 lbs (26.3 kg)*

Coverage (estimated):
165-265 sf/gal. pail (15-25 sm)
825-1325 sf/5 gal. (77-123 sm)
@ 6 mils wet; 2.9 mils dry (2-coats required)

Drying Time
@ 50% RH: temperature and humidity dependent

@ 38°-45°F: Touch: 2 hours,
Recoat: 24-48 hours

@ 45°F+: Touch: 1 hour,
Recoat: 4 hours

Volume Solids: 48 ± 2%*
Weight Solids: 65 ± 2%*
Weight per Gallon: 12.4 lb*

Application Range: 38º-110ºF (3.3º-43ºC)

Shelf Life: 2 years


Technical Data

Water Vapor Transmission (perms), ASTM E96 Wet Cup: 50

Modulus Properties (ASTM D412), Tensile Strength (psi): 294.3, Elongation %: 16.7

Adhesion, ASTM C719 (dry): 4.3, ASTM C719 (wet): 0.7

Wind Driven Rain, ASTM D6904: <0.1 lb Hydrophobicity, Contact Angle Initial/5 min. dwell: Before Accelerated Weathering 117.5/73.9 After 100 h Weatherometer 148.0/142.5 After 500 h Weatherometer 156.6/148.8 After 1000 h Weatherometer 156.9/152.0 Hazard: This chemical is not considered hazardous according to the OSHA Hazard Communication Standard 2012 (29 CFR 1910.1200). VOC: Less than 50 g/L. Volume Solids: 48 ± 2%* Weight Solids: 65 ± 2%* Weight per Gallon: 12.4 lb* *White Base value, may vary by base.


Approved Surfaces³

Stucco/EIFS/Textured Acrylic Finishes¹
Cement Composition Siding/Panels
Brick¹
Concrete¹
Masonry¹
Aluminum & Aluminum Siding²
Plywood
Wood
Vinyl Siding
Others approved in writing

1. Surfaces with a pH greater than 9 must be primed with a high pH-resistant coating such as Master Wall® Primecoat Primer or other acrylic-finish compatible primer.
2. On large expanses of metal siding, the air, surface, and material temperatures must be 50°F or higher.
3. Standard latex primers cannot be used below 50°F. See specific primer label for that product’s application limitations. Knots and some woods, such as redwood and cedar, contain a high amount of tannin, a colored wood extract. If applied to these bare woods, the first coat of SuperiorCote HP Coating may show some staining, but it will be trapped in the first coat. A second coat will uniform the appearance. If staining persists, spot prime severe areas with 1 coat of Exterior Oil-Based Wood Primer then topcoat with SuperiorCote HP.

*White Base value, may vary by base.


Application Temperature: 38°-110°F (3.3°-43°C) • Working Time: 1/2 hr • Dry Time:
@ 50% RH: temperature and humidity dependent
@ 38°-45°F: Touch: 2 hours, Recoat: 24-48 hours
@ 45°F+: Touch: 1 hour, Recoat: 4 hours


Application Procedure

SURFACE PREPARATION PRECAUTIONS
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.

Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Scrape and sand peeled or checked paint to a sound surface. Sand glossy surfaces dull. Sand hard surfaces, such as metal, to provide better adhesion. Seal stains from water, smoke, ink, pencil, grease, etc. with the appropriate primer/sealer.

SURFACE PREPARATION
Mildew: Remove before painting by washing with a solution of 1 part liquid bleach and 3 parts water. Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes. Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach/water solution.

APPLICATION
When the air temperature is at 38°F, substrates may be colder; prior to painting, check to be sure the air, surface, and material temperature are above 38°F and at least 5°F above the dew point. Avoid using if rain or snow is expected within 2-3 hours.

Do not apply at air or surface temperatures below 38°F or when air or surface temperatures may drop below 38°F within 48 hours. No reduction necessary.

Brush: Use a nylon/polyester brush.
Roller: Use a high quality polyester roller cover, 3/8” to 3/4” nap.
Spray—Airless
Pressure ………………………….. 2000 psi
Tip ……………………………… .015″-.019″

Apply two coats of SuperiorCote HP for proper performance. Hydrophobic properties will not develop immediately and are UV dependent. It may take up to 30 days before hydrophobic properties are visible.

CLEANUP INFORMATION
Clean spills, spatters, hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with mineral spirits to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using mineral spirits.

CAUTIONS
Mildew Resistant This coating contains agents which inhibit the growth of mildew on the surface of this coating film. Protect from freezing. Non-photochemically reactive.

LABEL CAUTIONS
Use only with adequate ventilation. To avoid overexposure, open windows and doors or use other means to ensure fresh air entry during application and drying. If you experience eye watering, headaches, or dizziness, increase fresh air, or wear respiratory protection (NIOSH approved) or leave the area. Avoid contact with eyes and skin. Wash hands after using. Keep container closed when not in use. Do not transfer contents to other containers for storage. FIRST AID: In case of eye contact, flush thoroughly with large amounts of water. Get medical attention if irritation persists. If swallowed, call Poison Control Center, hospital emergency room, or physician immediately. WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. DO NOT TAKE INTERNALLY. KEEP OUT OF THE REACH OF CHILDREN.

Health & Safety
WARNING!
Causes eye and skin irritation.
Precautionary Statement
Wash hands thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection.
FIRST AID MEASURES
Eye Contact: Immediately flush eyes with plenty of water for at least 15 to 20 minutes. Ensure adequate flushing of the eyes by separating the eyelids with fingers. Get immediate medical attention.
Skin Contact: Immediately wash skin with plenty of soap and water for 15 to 20 minutes, while removing contaminated clothing and shoes. Get medical attention if irritation develops or persists.
Inhalation: If inhaled, remove to fresh air. If not breathing, give artificial respiration or give oxygen by trained personnel. Seek immediate medical attention.
Ingestion: If swallowed, do NOT induce vomiting. Call a physician or poison control center immediately. Never give anything by mouth to an unconscious person.
Store locked up. Dispose of contents/container in accordance with Local, State, Federal and Provincial regulation.
Spills: Collect with suitable absorbent material such as cotton rags.
Disposal: Dispose of in accordance with local, state or federal regulations.
Warning: KEEP CONTAINER CLOSED WHEN NOT IN USE. KEEP OUT OF THE REACH OF CHILDREN. NOT FOR INTERNAL CONSUMPTION. FOR INDUSTRIAL USE ONLY. Consult the Safety Data Sheet (SDS) in the Products section at masterwall.com for further health and safety information.

LIMITED WARRANTY
This product is subject to a written limited material or system warranty. Obtain a warranty from the Tech Support tab of our website. Refer to Specifications for more complete information on proper use and handling of this product.

Information contained in this product data sheet conforms to the standard detail recommendations and specifications for the installation of Master Wall Inc.® products and is presented in good faith. Master Wall Inc.® assumes no liability, expressed or implied as to the architecture, engineering, or workmanship of any project. This information may be concurrent with, or superseded by other applicable documents, such as specifications and details. Contact Master Wall Inc.® for the most current product information. ©2019 Master Wall Inc.®